Time of Day Display Offset
The time of day displayed on CT2002 displays slaved from upstream GPS or
Master clocks or triggered by top-of-hour input closures can be offset by any
amount of seconds, minutes, or hours. Typical applications ofr such an offset:
•Network Top-of-hour pulses sent early (seconds before the
actual top-of-hour)
• Stations running in full obsentity delay
• HD station transmission delay
• Time zone multi clock displays
To offset closure reset:
Use the infrared remote control option 10 position to enter the minutes and
or seconds desired to be displayed when the top of hour closure is received.
• Note that hours displayed will not be affected.
• Note that top-of-hour is only active prior to and after the hour (to avoid
false triggers at other times).
• See manual page 12 for programming instructions.
To offset serial time input from and upstream GPS or Master clock in
the serial chain (RS serial time code or SMTPE time code allowed):
Use the infra red remote control to input hours to be added to time of day
serial data (option 4), or minutes and or seconds to be added to the time of
day serial data (option 11).
• Note that offsets are always added to the stream. For example:
To offset plus 1 hour, 10 seconds - set option 4 for 01 and
option 11 for 00:04
To offset minus 8 seconds - set option 4 for 23 and
option 11 for 00:52